The 20-03 is an I/O expander Module which provides four relay outputs, plus eight open drain I/O pins which also serve as inputs.
The 20-03 is an I/O expander Module which provides four relay outputs, plus eight open drain I/O pins which also serve as inputs.
The 20-03 is an I/O expander Module which provides four relay outputs,
plus eight open drain output pins which also serve as inputs.
The 20-03 outputs can be activated by Salcom Relay Protocol or other ASCII text over a serial connection.
Salcom Relay Protocol commands may be embedded in a POCSAG message received by a 20-90 transceiver, allowing activation of outputs by remote POCSAG transmitters.
Activation by POCSAG messages can be limited to a CAP code range, or
outputs can be triggered by any message sent to a CAP code within a range. Outputs may also be configured to respond to any specified text within the serial data.
Inputs on the 20-03 can generate Salcom protocol POCSAG messages over a serial connection which can be transmitted to a pager by a Salcom 20-90 transceiver or a Salcom 20-62 transmitter. Alternatively, inputs can be configured to send any ASCII text over the serial connection in response to an input change.
Power Supply | +13.8V typical (11 to 15 VDC range) |
Power Consumption | Normal Operation: 15mA Relays: 20mA per energized relay |
Configuration Application | Salcom Configuration Tool (Sacoto) |
Programming Cable | 12-45-0000 (RJ12 to DB9) Can be used with a USB to RS232 DB9 Serial Adapter Cable |
Serial Port | 2 ports, 9600, N, 8, 1; RS232 |
Serial Protocols | Salcom Relay protocol Salcom Message protocol ASCII strings to trigger outputs ASCII messages triggered by inputs Multiple units may be daisy-chained for additional inputs or outputs, or to create a bi-directional link between inputs and outputs on separate units. |
Relay Outputs | 4 Relays with normally open and normally closed contacts 1A@4Vdc |
Open Drain Outputs | Eight open drain outputs with 500mA resettable fuses (PTC). Selectable as 5mA current limited. Internal protection for inductive loads. Maximum voltage = supply voltage. |
Inputs | 8 inputs monitoring the open drain outputs. Open drain outputs have an internal pull-up to 3.3v (4k) and maybe pulled low externally. |
Connectors | Two-way pluggable DC power connector Serial Port 1 (RS232) = RJ12 (6P6C) Serial Port 2 (RS232) = RJ12 (6P6C) Terminal block: 2 rows x 12 way, 3.81mm pitch. Two 12-way plugs with screw connections (supplied) |
Environmental Protection | Not suitable for outdoor use and should be protected from adverse environmental conditions |
Operating Temperature | -10°C to +50°C (+14°F to +122°F) |
Indicators | Power LED (Green) Slow Flashing = Normal Operation Data LED (Red) On = Active Serial Data Flashing = Programming Mode |
Weight | 250g |
Enclosure Dimensions | 68mm x 150mm x 38mm (WxDxH) |
Enclosure Material | Extruded aluminum |
Colour | Matt Black |
Compliance | EN 301 489-2 (V2.1.1, 2019-04) |
The 20-03 is an I/O expander Module which provides four relay outputs,
plus eight open drain output pins which also serve as inputs.
The 20-03 outputs can be activated by Salcom Relay Protocol or other ASCII text over a serial connection.
Salcom Relay Protocol commands may be embedded in a POCSAG message received by a 20-90 transceiver, allowing activation of outputs by remote POCSAG transmitters.
Activation by POCSAG messages can be limited to a CAP code range, or
outputs can be triggered by any message sent to a CAP code within a range. Outputs may also be configured to respond to any specified text within the serial data.
Inputs on the 20-03 can generate Salcom protocol POCSAG messages over a serial connection which can be transmitted to a pager by a Salcom 20-90 transceiver or a Salcom 20-62 transmitter. Alternatively, inputs can be configured to send any ASCII text over the serial connection in response to an input change.
Power Supply | +13.8V typical (11 to 15 VDC range) |
Power Consumption | Normal Operation: 15mA Relays: 20mA per energized relay |
Configuration Application | Salcom Configuration Tool (Sacoto) |
Programming Cable | 12-45-0000 (RJ12 to DB9) Can be used with a USB to RS232 DB9 Serial Adapter Cable |
Serial Port | 2 ports, 9600, N, 8, 1; RS232 |
Serial Protocols | Salcom Relay protocol Salcom Message protocol ASCII strings to trigger outputs ASCII messages triggered by inputs Multiple units may be daisy-chained for additional inputs or outputs, or to create a bi-directional link between inputs and outputs on separate units. |
Relay Outputs | 4 Relays with normally open and normally closed contacts 1A@4Vdc |
Open Drain Outputs | Eight open drain outputs with 500mA resettable fuses (PTC). Selectable as 5mA current limited. Internal protection for inductive loads. Maximum voltage = supply voltage. |
Inputs | 8 inputs monitoring the open drain outputs. Open drain outputs have an internal pull-up to 3.3v (4k) and maybe pulled low externally. |
Connectors | Two-way pluggable DC power connector Serial Port 1 (RS232) = RJ12 (6P6C) Serial Port 2 (RS232) = RJ12 (6P6C) Terminal block: 2 rows x 12 way, 3.81mm pitch. Two 12-way plugs with screw connections (supplied) |
Environmental Protection | Not suitable for outdoor use and should be protected from adverse environmental conditions |
Operating Temperature | -10°C to +50°C (+14°F to +122°F) |
Indicators | Power LED (Green) Slow Flashing = Normal Operation Data LED (Red) On = Active Serial Data Flashing = Programming Mode |
Weight | 250g |
Enclosure Dimensions | 68mm x 150mm x 38mm (WxDxH) |
Enclosure Material | Extruded aluminum |
Colour | Matt Black |